Advanced Differential Pressure Transducer for Building Control Systems

Product Details
Customization: Available
Type: Differential Pressure Transmitter
Structure Type: HVAC Micro Differential Pressure Transmitter Senso
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
53
Year of Establishment
2010-07-29
  • Advanced Differential Pressure Transducer for Building Control Systems
  • Advanced Differential Pressure Transducer for Building Control Systems
  • Advanced Differential Pressure Transducer for Building Control Systems
  • Advanced Differential Pressure Transducer for Building Control Systems
  • Advanced Differential Pressure Transducer for Building Control Systems
  • Advanced Differential Pressure Transducer for Building Control Systems
Find Similar Products

Basic Info.

Measuring Medium
Dry Air
Accuracy Grade
0.5G
Pressure range
-10kpa~0~10kpa
IP Rating
IP65
Certification
CE
Customized
Customized
Item
DPT Differential Pressure Transmitter Pressure Sen
Output
4-20mA , 0-5V,0-10V, RS485
Thread
1/8NPT
Wetted Part
ABS Plastic
Case Material
ABS Plastic
Pressure Type
Differential Pressure
Power Supply
12~36VDC
Temperature
-20~60c
Transport Package
Standard Package
Specification
0.25kg
Trademark
YUNYI
Origin
China
HS Code
9026201090
Production Capacity
10000

Product Description

LCD display differential pressure transmitter, differential pressure transducer for building automation 


YUN YI ,we are professional manufacturer that engaged in the fields of pressure measurement instrument. Our company mainly produces pressure transmitter, ceamic pressure transmitter, temperature transmitter. flush disphragm pressure transmitter, smart digital pressure transmitter, wirelss pressure transmitter etc.
Advanced Differential Pressure Transducer for Building Control SystemsAdvanced Differential Pressure Transducer for Building Control SystemsAdvanced Differential Pressure Transducer for Building Control SystemsAdvanced Differential Pressure Transducer for Building Control SystemsAdvanced Differential Pressure Transducer for Building Control Systems

Decription of LCD display differential pressure transmitter, differential pressure transducer for building automation

LCD display differential pressure transmitter, differential pressure transducer for building automation is suitable for differential  pressure measurement of dry gas. It is the responsibility of the operator to verify that the equipment is suitable for the operating conditions of the application. If you have any questions, please contact our sales department to ensure the correct application of the transmitter. The company will not take any responsibility for the impact caused by improper selection.
LCD display differential pressure transmitter, differential pressure transducer for building automation adopts piezoresistive pressure sensor chip, and uses the film resistance on the substrate to carry out zero point correction, zero point temperature compensation and sensitivity compensation. The high-performance and stable silicon chip package makes it high static pressure resistance, anti-interference, stable and reliable.


Detailed picture of 
LCD display differential pressure transmitter, differential pressure transducer for building automation

   
   

 

Technical Parameters of LCD display differential pressure transmitter, differential pressure transducer for building automation

Item LCD display differential pressure transmitter, differential pressure transducer for building automation
Measuring medium gas (compatible with contact material, humidity <90%, no condensation)
Overall material shell ABS engineering plastic
LCD display without backlight
Mounted Φ 6 pagoda mouth H59 copper (contact)
Range 0~±0.1~±10KPa
Pressure mode differential pressure
Output signal 4-20mA, RS485, 0-10V
Power supply voltage 12-36vdc
Accuracy class 0.5% FS (range ≥ 1kPa)  1% FS (range < 1kPa)
Working conditions medium temperature - 40-100 ºC
Ambient temperature -40-85 ºC
Temperature compensation -10 ~ 60 ºC
Seismic performance 10g (20... 2000Hz)
Response frequency ≤ 50Hz
Stable performance ±0.3% FS / year (range ≥ 1kPa)       ± 0.5% FS / year (range < 1kPa)
Temperature drift ± 0.03% FS / ºC (within the temperature compensation range)
Overall weight with display ≈ 150g, without display ≈ 130g
Protection grade IP65
Upper power limit current type ≤ 0.02us (W)
Digital type 0.015us (W)
Load characteristics current type load ≤ {(us-7.5) ÷ 0.02 (US =  supply voltage)} Ω

 

Application of LCD display differential pressure transmitter, differential pressure transducer for building automation
Medical equipment
HVAC
Industrial control
Building automation

Feature of LCD display differential pressure transmitter, differential pressure transducer for building automation
a) Integrated chip, wide voltage power supply
b) Frequency intercept design, strong anti-interference ability and
lightning protection
c) Current limiting, voltage limiting, reverse connection protection
(current limiting output)
d) High precision and stability
e) Self correcting zero point