Basic Info.
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Product Description
Description electromagnetic flow meter remote digital display water transmitterIntelligent electromagnetic flowmeter consists of two parts, the sensor and converter. It is based on the work of Faraday's law of electromagnetic induction, used to measure the conductivity is greater than 5μS / cm conductive liquid volumetric flow rate, is a measure of the volume flow of conductive medium for induction meter. In addition to measure the volume flow of conductive liquid, it can also be used to measure the volume of a homogeneous liquid-solid two-phase flow of a liquid suspension of acid and alkali and other strong corrosive liquids and slurries, pulp and paper pulp.Widely used in flow measurement of petroleum, chemical, metallurgy, textile, paper, environmental protection, food and other industrial and municipal administration, water conservancy construction, river dredging and other fields.Detailed Images electromagnetic flow meter remote digital display water transmitterSpecification of electromagnetic flow meter remote digital display water transmitterNominal Diameter(mm) (Special specifications can be customized) | pipeline tetrafluoroethylene lining:DN10~DN2600 |
Pipeline rubber lining:DN40~DN2600 |
Flow direction: | positive and negative, the net flow |
Turndown ratio: | 1500:1 |
Repeatability error: | ± 0.1% of measured value |
Accuracy: | Pipeline:0.5,1.0 |
Measured medium temperature: | ordinary rubber lining::-20~+60ºC |
High-temperature rubber lining: -20~+90ºC |
PTFE lining:-30~+120ºC |
High temperature tetrafluoroethylene lining:::-20~+180ºC |
Rated working pressure: (High voltage can be customized) | DN6-DN80:≤2.5MPa |
DN100-DN250:≤1.6MPa |
DN300-DN2600:≤1.0MPa |
Flow rate range: | 0.1-15m/s |
Conductivity range: | the measured fluid conductivity≥5μs/cm |
Current output: | load resistance | 0~10mA:0~1.5kΩ |
4~20mA:0~750 kΩ |
Digital frequency output: | transistor output frequency limit can be set with optical isolation within 1 ~ 5000HZ bidirectional open-collector output. External power supply is turned ≤35V maximum collector current of 250mA |
Power supply: | AC220Vor DC24V |
Length of straight pipe requirements | upstream≥5DN,downstream≥2DN |
Connection: | are used between the meter and piping flange connection, flange dimensions shall comply with the provisions of GB11988 |
Explosion levels | mdIIBT4 |
Protection class: | IP65,special order up to IP68 |
Ambient temperature: | -25~+60ºC |
Relative humidity: | 5%~95% |
Total power consumption: | less than 20W |
Measure range
Inner diameter(mm) | 10 | 15 | 20 | 25 | 32 | 40 | 50 | 65 |
Qmin(m3/h) | 0.0283 | 0.0636 | 0.12 | 0.176 | 0.29 | 0.452 | 0.7 | 1.19 |
Qmax(m3/h) | 4.24 | 9.54 | 16.96 | 26.5 | 43.42 | 67.85 | 106.0 | 179.0 |
Inner diameter(mm) | 80 | 100 | 125 | 150 | 200 | 250 | 300 | 350 |
Qmin(m3/h) | 1.8 | 2.82 | 4.41 | 6.36 | 11.3 | 17.6 | 25.4 | 34.6 |
Qmax(m3/h) | 271.0 | 424.0 | 662.0 | 954.0 | 1690 | 2650 | 3810 | 5190 |
Inner diameter(mm) | 400 | 450 | 500 | 550 | 600 | 700 | 800 | 900 |
Qmin(m3/h) | 45.2 | 57.2 | 77.6 | 85.5 | 101.0 | 138.0 | 180.0 | 229.0 |
Qmax(m3/h) | 6780 | 8570 | 10600 | 12800 | 15200 | 20700 | 27100 | 34300 |
Inner diameter(mm) | 1000 | 1100 | 1200 | 1400 | 1600 | 1800 | 2000 | 2200 |
Qmin(m3/h) | 282.0 | 342.0 | 407.0 | 554.1 | 732.7 | 916.0 | 1131.0 | 1368.4 |
Qmax(m3/h) | 42400 | 51300 | 61000 | 83121 | 108566 | 137404 | 169635 | 205258 |
Select the lining materialShould be based on the measured medium temperature corrosive wear and to select the lining material Lining material | corrosion resistance | Working temperature | Application |
Ne | General resistance to low concentrations of acid salt corrosion | -20~70ºC | lower industrial water effluent pH and salt concentration |
PO | Has an excellent wear resistance, abrasion resistance slurry dedicated to strong, not decay | -10~60ºC | Liquids containing solid particles (slurry pulp, etc.) |
FEP | 1 corrosion resistant and quite PTFE 2 high mechanical strength, good wear resistance 3 table smooth, easy adhesion precipitate 4 have strong abrasive media fluid good resistance to outside negative, anti-vacuum effect | -40~180ºC | except mortar. Like with PTFE can be used for drinks and other health requirements of the media |
PTFE | lmost all of the corrosion resistant chemical media, poor wear resistance | -40~180ºC | Not be used for pipes and wear strong negative fluid |
Selective Electrode MaterialsShould be based on the measured fluid corrosive to select material of the electrodes, check the manual for special fluids should be corrosion test Material | Code | corrosion resistance |
316Lstainless steel | V | 1 applies to a neutral solution of industrial, domestic water, raw water wells, urban sewage 2 weak corrosive acids, bases, salts medium such as carbonic acid, acetic acid, etc. |
Hastelloy C | HC | 1 applies to anti-oxidizing acids, such as a mixture of nitric acid, mixed acid, chromic acid and sulfuric acid 2 oxidation resistance salt or other corrosive environments, such as the oxidant Fe, Cu 3 Sea water, alkali solution, the oxide solution has excellent corrosion resistance 4 NA: hydrochloric acid |
Hastelloy B | HB | 1 for the non-oxidizing acids, bases, salts such as sulfuric acid, phosphoric acid, hydrofluoric acid has good corrosion 2 NA: nitrate |
|
Titanium | Ti | seawater resistant, various chlorides suddenly hypochlorite and a variety of corrosion hydroxide |
Ta | Ta | except hydrofluoric acid, almost all corrosive chemical media capability. But expensive |
Platinum | Pt | salt solution applicable to all of the acid (fuming sulfuric acid and nitric acid) |
Tungsten | W | has excellent wear resistance, dedicated to the mud, pulp and other abrasive media |
Features of electromagnetic flow meter remote digital display water transmitter- Fully digital processing, anti-interference ability, reliable measurement, high accuracy flow measurement range up to 1500: 1
- Ultra-Low EMI switching power supply for supply voltage variation range, anti-EMI performance.
- 16-bit embedded microprocessors, computing speed, high precision, programmable low-frequency square wave excitation frequency and improve the stability of the flow measurement, low power consumption.
- using SMD devices and surface mount (SMT) technology, circuit reliability.
- No moving parts inside the pipe l, unimpeded flow of parts, measuring almost no additional pressure loss.
- range in the field can be modified online according to the actual needs.
- measurements and velocity distribution, the physical parameters of the fluid pressure, temperature, density, viscosity and the like.
- High-resolution backlit LCD display, full Chinese menu, easy to use, simple to operate, easy to understand.
- have RS485, RS232, Hart, and Modbus and other digital communication signal output. (Optional)
- has a self-test and self-assertion.
- total hourly recording function to record the total flow in units of hours for hourly metering system (optional)
- have three internal totalizer can show the cumulative amount of forward and reverse cumulative amount of the difference between the volume totalizer, the internal power-down features not always, can record 16 power-down times. (Optional)
- IR handheld operator, 115KHZ communication speed, long-distance non-contact operation of all functions converter (optional)
Order guide electromagnetic flow meter remote digital display water transmitter
Model number | Directions |
LDG - | | | | | | | | | |
Path | | | | | | | | | | 10-2600mm |
Combination | S | SpliT |
C | Compact |
Electrode material | M | SS |
T | Ti |
D | Ta |
H | Hastelloy |
P | Pt |
N | Ni |
Output mode | 0 | No output |
1 | 4-20mA/1-5KHz |
2 | 4-20mA |
Lining material | X | Rubber |
F | Teflon |
P | Polyethylene |
J | Polyurethane |
Local display | 0 | no |
1 | yes |
Communication | 0 | no |
1 | RS485 |
2 | RS232 |
3 | Mobdus |
4 | Hart |
Ground | 0 | No grounding ring |
1 | grounding ring |
2 | The ground electrode |
Limit traffic | (n) | Limit the flow (range) m3 / h |
Example: use of a local display type electromagnetic flowmeter sewage pipes for user DN50, require rubber lining, stainless steel electrodes, 4 ~ 20mA output, no communication, limit the flow of 30m3 / h. Models should be: LDG-50S-M1X100-30
Address:
Room B1203, Inland Port Mansion, No. 9 Gangwu Road, Xi an International Trade & Logistics Park, Xi′an, Shaanxi, China
Business Type:
Manufacturer/Factory
Business Range:
Auto, Motorcycle Parts & Accessories, Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters, Manufacturing & Processing Machinery, Tools & Hardware, Transportation
Management System Certification:
ISO 9000
Company Introduction:
Xian Yunyi Instrument Co., Ltd. is a professional manufacturer that engaged in the fields of pressure measurement instrument, the chief engineer, Mr Tian has more than 30 years experience on this area, and he is one of the engineers who introduced the Rosemount technology.
YUN YI, we are professional manufacturer that engaged in the fields of pressure measurement instrument.
We have 12 years sensor producing and developing experiences
12 moths warranty
OEM& ODM
Near 1/2 buyers found pressure sensor & Contact us
Our company offers variety of products which can meet your multifarious demands. We adhere to the management principles of "quality first, customer first and credit-based" since the establishment of the company and always do our best to satisfy potential needs of our customers. Our company is sincerely willing to cooperate with enterprises from all over the world in order to realize a win-win situation since the trend of economic globalization has developed with anirresistible force.