Clamp Flow Meter Without LCD Display

Product Details
Customization: Available
Accuracy: 0.1% Fs 0.16% Fs 0.25% Fs
Type: Calibration Equipment
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
53
Year of Establishment
2010-07-29
Find Similar Products

Basic Info.

Model NO.
ZFG
Product Name
Clamp Flow Meter Without LCD Display
Connection
Flange, Thread
Linning Material
PTFE
Conductivity Range
> 5μs/Cm
Protection Level
IP65, IP68 (Optional)
Medium Type
Liquid
Power Supply
220VAC/ 24VDC
Flow Rate Range
15m/S
Nominal Diameter
DN10~DN3000
Transport Package
Carton
Trademark
YUNYI
Origin
China
HS Code
9026201090
Production Capacity
500PCS/Week

Product Description

Clamp flow meter without LCD display

Description  

ZFG series a shape by electromagnetic flow meter ZFG type electromagnetic flowmeter sensor and signal converter matching integrated ZFH series, signal converter with IP67 protection requirements. ZFG electromagnetic flowmeter is mainly used to measure a size All kinds of acid, alkali, salt solution, pulp, mud, such as electrical conductivity of liquid, or the volume flow of liquid-solid two-phase medium. In the chemical industry, mining and metallurgy, water supply and drainage, sewage treatment, food, papermaking, sugar-making, port dredging departments should be widely To use. This flow meter and display, recording instrument, integrator or regulator, used to test the flow, integrating, adjusting and control.

Detailed Images  
Specification 

 

electromagnetic electromagnetic flow meter without LCD display

Conductivity Range

The measured fluid condutivity≥5μs/cm

Load Resistance

0 ~ 10mA 0 ~ 1.5KΩ

Current Output

4 ~ 20mA 0 ~ 750KΩ

Digital Frequency Output

Transistor output frequency limit can be set with optical isolation within 1~5000Hz bidirectional open-collector output. External power supply is turned ≤35V maximum collector current of 250mA

Power Supply

AC 220V Or DC 24V

Length Of Straight Pipe Requirements

Up Stream≥5DN, Down Stream≥2DN

Connection

are used between the meter and piping flange connection, flange dimensions shall comply with the provisions of GB11988

Explosion Levels

Exd II BT4

Protection Class

IP65, Special Order up to IP68

Ambient Temperature

-25ºC ~ +60ºC

Relative Humidity

5% ~ 95%

Total Power Consumption

Less Than 20W

 

Lining Material 

 

Lining material

corrosion resistance

Working temperature

Application

Ne

General resistance to low concentrations of acid salt corrosion

-20~70ºC

lower industrial water effluent pH and salt concentration

PO

Has an excellent wear resistance, abrasion resistance slurry dedicated to strong, not decay

-10~60ºC

Liquids containing solid particles (slurry pulp, etc.)

FEP

1 corrosion resistant and quite PTFE
 2 high mechanical strength, good wear resistance
3 table smooth, easy adhesion precipitate
 4 have strong abrasive media fluid good resistance to outside negative, anti-vacuum effect

-40~180ºC

except mortar. Like with PTFE can be used for drinks and other health requirements of the media

PTFE

almost all of the corrosion resistant chemical media, poor wear resistance

-40~180ºC

Not be used for pipes and wear strong negative fluid

 

Features 

1. The sensor adopts overall welding structure, good sealing 
2.  Record the measurement from the measured media pressure, temperature, density, viscosity and other physical parameters
3. With functions of conductivity measurement, can distinguish whether the sensor controller 
4. Using 16-bit embedded microcontroller processor, a fast calculation speed, high precision 
5.  With two-way flow measurement function, can show positive and reverse flow, percentage, velocity of flow
6.  With two-way flow measurement function, can show positive and reverse flow, percentage, velocity of flow
7.  Digital content processing, strong anti-interference ability, reliable measurement, high precision
8. Low EMI switch power supply for power supply voltage change fan at large, the EMC performance is good
9.  Since the diagnosis information and troubleshooting
10.  Can provide explosion-proof type

 

Selection Guide 

 

Example:local display type electromagnetic flowmeter sewage pipes for user DN50, require rubber lining, stainless steel

electrodes,4 ~ 20mA output, no communication, limit the flow of 30m3 / h. Models should be: LDG-50S-M1X100-30

Related Products

FAQ

Q:How long will you reply me?

A:We will contact you as soon as possible but within 12 hours

Q: Can I get some samples?

A: Yes, Sample order is available for quality check and market test. But you have to pay the express cost.

Q: How soon can you arrange your production?

A: Once getting your product confirmation and receiving the prepayment, the production will be started immediately.

Q: What's delivery time?

A: It usually takes about 3-5 working days for small order and 10-15 days for big order.

Q:How do you control your quality ?

A: Three inspection steps(of original, production, and finished goods) + good warranty service(1 year free to change a new one without any human damage factors).

Q: What certificates do you have ?

A:ISO9000, CE, Explosion-proof certification, RoHs ready. And before the delievry of goods, quality and safety inspection certification issued by third parts also can be offered.

Q:Could I visit your factory?

A:Very welcome! Fly to Xian Yang air port. It was a big pleasure for us.

Q: What's your warranty terms?

A: We offer 12 months warranty time.

Q:can you provide OEM & Customized service?

A:Yes, OEM and ODM are both available, we have the professional R&D dept which can provide professional solutions for you.


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier